Bosch Rexroth 4WE 6 is a Size 6 (NG6), component series 6X direct-operated solenoid directional spool valve that controls the start, stop, and direction of hydraulic flow in 4/3-way, 4/2-way, or 3/2-way configurations. Rated to 350 bar [5076 psi] and up to 80 l/min [21 US gpm] with DC solenoids (60 l/min [15.8 US gpm] with AC), it mounts on standard ISO 4401-03-02-0-05 and NFPA T3.5.1 R2-2002 D03 interfaces.

Applications and Operating Media

Bosch Rexroth 4WE 6 valves are standard subplate-mounted directional controls across machine tools, presses, injection molding machines, hydraulic power packs, and mobile or marine manifolds.

Hydraulic Fluid GroupFluid ClassificationCompatible Seal CodeReference Standard
Mineral oilsHL, HLP, HLPD, HVLP, HVLPDNBR (no code), FKM (V)DIN 51524
Bio-degradable (water-insoluble)HETG, HEESFKM (V)ISO 15380
Bio-degradable (water-soluble)HEPGFKM (V)ISO 15380
Flame-resistant (water-free)HFDU (glycol / ester base), HFDRFKM (V)ISO 12922
Flame-resistant (water-containing)HFCNBR / MH (high-temp HFC)ISO 12922

Operating notes from RE 23178:

  • For water-containing HFC fluids, limit ambient and fluid temperature to 50 °C and set continuous on/off duty cycle to 50% (300 s period) or use a PWM energy-reduction connector (VT-SSBA1-PWM-1X/V002/5, R901290194).
  • Separate return lines or a tank-line check valve are recommended for OF detent valves to prevent tank pressure peaks from shifting the spool unintentionally.

Features

  • High-power detachable wet-pin solenoids rotatable by 90°, available in DC (12 to 220 VDC) and AC (100 to 230 VAC 50/60 Hz) with 100% continuous duty rating (S1 per VDE 0580).
  • Wide connection ecosystem: individual plugs (K4 DIN EN 175301-803 IP65, K4K IP65/IP67, K40 Deutsch IP69K, K72L/K73L M12x1 IP65, C4 Junior-Timer IP66) or central terminal boxes (DL, DAL, DK6L, DK23L/DK25L, DK24L).
  • Optional smooth-switching spool design (.73...A12) reducing switching acceleration shocks by up to approximately 85%, plus optional inductive spool position monitoring (QM, QR, QS).
  • Optional reduced-power 8 W DC version (SO407, 315 bar / 60 l/min, 85 °C max coil surface temperature) and UL 906 (=UR) / CSA (=CSA) approvals.
  • Reliability rating MTTFD = 300 years according to EN ISO 13849 (data sheet 08012).

Technical Data

ParameterDC VersionAC Version (50/60 Hz)
Nominal size / Component seriesSize 6 / Component series 6XSize 6 / Component series 6X
Porting patternISO 4401-03-02-0-05 / NFPA D03ISO 4401-03-02-0-05 / NFPA D03
Max. operating pressure (Ports A, B, P)350 bar [5076 psi] (315 bar SO407)350 bar [5076 psi]
Max. operating pressure (Port T)210 bar [3050 psi]160 bar [2320 psi]
Maximum flow80 l/min [21 US gpm] (60 l/min SO407)60 l/min [15.8 US gpm]
Nominal power / Holding & switch-on30 W (8 W SO407; 34 W =UR)50 VA holding / 220 VA switch-on
Voltage tolerance / Duty cycle±10% / 100% (S1)±10% / 100% (S1)
Switching time ON / OFF (ISO 6403)25 to 45 ms / 10 to 25 ms10 to 20 ms / 15 to 40 ms
Max. switching frequency4.2 1/s (2 1/s SO407; 1 Hz w/ diode)2 1/s
Max. coil surface temperature120 °C [248 °F] (85 °C SO407)120 °C [248 °F]
Insulation class (VDE 0580)Class F (Class H for G12/G24 =UR)Class H
Hydraulic fluid temperature range-20 to +80 °C (NBR) / -15 to +80 °C (FKM) / -40 to +50 °C (MT)Same as DC
Ambient temperature range-20 to +50 °C (NBR) / -15 to +50 °C (FKM) / -40 to +50 °C (MT)Same as DC
Viscosity range2.8 to 500 mm²/s [35 to 2320 SUS]2.8 to 500 mm²/s [35 to 2320 SUS]
Max. fluid contamination (ISO 4406 (c))Class 20/18/15Class 20/18/15
MTTFD (EN ISO 13849)300 years300 years
Weight (1 solenoid / 2 solenoids)1.45 kg [3.2 lbs] / 1.95 kg [4.3 lbs]1.45 kg [3.2 lbs] / 1.95 kg [4.3 lbs]

Dimensions and Weights

Bosch Rexroth 4WE 6 valves fit standard ISO 4401-03-02-0-05 and NFPA T3.5.1 R2-2002 D03 subplates with either standard 42 mm [1.65 inch] or compact 22 mm [0.87 inch] (Z) clamping length.

Mounting & Weight ParameterSpecification
Weight — 1 solenoid (4/2-way or 3/2-way)1.45 kg [3.2 lbs]
Weight — 2 solenoids (4/3-way or detent)1.95 kg [4.3 lbs]
Mounting screws — 42 mm clamping length (4 pcs)ISO 4762 - M5 x 50 - 10.9-flZn-240h-L (R913043758), MA = 7 Nm [5.2 ft-lbs] ±10%
Mounting screws — 42 mm UNC option (4 pcs)10-24 UNC x 2” ASTM-A574 (R978800693), MA = 8 to 11 Nm
Mounting screws — 22 mm clamping length Z (4 pcs)ISO 4762 - M5 x 30 - 10.9-flZn-240h-L (R913048086), MA = 7 Nm [5.2 ft-lbs] ±10%
Mounting screws — 22 mm UNC option (4 pcs)10-24 UNC x 1 1/4” (R978802879), MA = 8 to 11 Nm
Coil mounting nut tightening torque4 (+1) Nm [2.95 (+0.74) ft-lbs]
K4 mating connector M3 screw max. torque0.37 ft-lbs (see RE 23178 item 10)
Required subplate flatness / roughness0.01/100 [0.0004/4.0] / Rzmax 4

Selection and Ordering Guide

Ordering code pattern: [3/4] WE 6 [Symbol] 6X / [O/OF] E [Voltage] [Override] [J3/J5] [Connector] [Switch] / [A12] [Throttle] [Z] [T06/T12] [Seal] [=UR/=CSA/=AN] [/62] [SO407]

Code FieldCommon OptionsDescription
Ports & Size4WE 6 / 3WE 64-port or 3-port direct-operated directional spool valve, Size 6
Spool Returnno code / O / OFSpring return (no code), without spring (O), or detent without spring (OF, symbols A, C, D)
Solenoid VoltageG12, G24, G110, W110, W230Wet-pin detachable coil E (24 VDC G24 rated 1.25 A; 230 VAC W230 rated 0.23 A @ 50 Hz)
Manual OverrideN9 / N / N4–N7 / no codeConcealed override (N9, standard), exposed (N), or lockable mushroom/nut (up to 50 bar tank pressure)
Electrical ConnectionK4, K40, K72L, C4, DL, DK6LStandard 3-pole DIN EN 175301-803 (K4, IP65) or IP69K Deutsch (K40) / M12x1 / central box
Corrosion Protectionno code / J3 / J5Primed housing, 240 h salt spray (J3), or 720 h salt spray (J5, EN ISO 9227)
Seal Compoundno code / V / MH / MTNBR (standard), FKM (V), high-temp HFC (MH), or low-temp -40 °C (MT)

Common separately ordered accessories:

  • Mating connector Z4 (for K4, 12 to 240 V, M16x1.5): solenoid a R901017010, solenoid b R901017011
  • Mating connector Z5L1 (24 V with indicator LED and Z-diode suppressor): R901017026
  • Locking pin ISO 8752-3x8-St (for /62 locating hole): R900005694

Technical FAQ

What is the maximum tank pressure when using the manual override on Bosch Rexroth 4WE 6? Manual override actuation is permitted only up to 50 bar [725 psi] tank pressure. Above 50 bar, lockable overrides (N4, N5, N7) cannot be guaranteed to stay latched, and the manual override must never be assigned a safety function.

Can Bosch Rexroth 4WE 6 be fitted with throttle inserts inside ports P, A, B, or T? Yes. When switching flows exceed the valve performance limit, factory throttle inserts from 0.6 mm to 4.0 mm can be ordered directly in port P (=B06 to =B40), port A (=H06 to =H40), port B (=R06 to =R40), ports A and B (=N06 to =N40), or port T (=X06 to =X40).

How does the optional SO407 low-power version differ from standard 4WE 6? Version SO407 (available for 24 VDC G24 with K4, DL, or DKL) cuts nominal coil power from 30 W to 8 W and lowers maximum coil surface temperature from 120 °C to 85 °C, with a rated limit of 315 bar, 60 l/min, and 2 switches per second.

Specify 4WE 6, spool symbol, spring/detent code, solenoid voltage, electrical connector, seal compound, and quantity when requesting a quotation.